Sourcing workspace
Profile updated 19 Oct 2026

Luksens Technologie GmbH

Also known as Luksens

ManufacturerLocations reported in Hong Kong SAR China · China · Germanyluksens.com
AI visibility scorecardHow much can an AI assistant tell a buyer about Luksens Technologie GmbH?We scored this profile on the 8 questions buyers’ AI agents ask first, and ranked it against similar suppliers nearby.See the score

About

Luksens offers technical support and delivery to the global sensor market.

The company states that it has worked with pressure and current sensors since 2001.

Products

18 listed
C10M Series | 2 MHz (GaN-optimized) ICS

C10M Series | 2 MHz (GaN-optimized) ICS

Fully integrated differential Hall-effect current sensor with differential outputs, temperature and stress compensation, and adjustable FAULT overcurrent detection. Features 2 MHz bandwidth, 5 kVrms isolation, and 200 μΩ primary resistance; optimized for SiC and GaN-based power electronics.

Source & evidence

Supplier website
The C10M is a high-performance, fully integrated Hall-effect current sensor employing a differential architecture to effectively suppress external common-mode magnetic interference. It provides a pair of differential outputs (OUT and REF) to maximize the signal-to-noise ratio (SNR) in noisy environments, while integrated temperature and stress compensation ensures high accuracy over a temperature range of -40°C to +125°C, and feature a FAULT overcurrent detection with an externally adjustable overcurrent threshold, saving the cost of additional board-level comparators. The C10M features a 2 MHz (3dB) bandwidth, 5 kVrms isolation, and an ultra-low 200 μΩ primary resistance, optimized for the high-frequency, fast switching requirements of SiC and GaN-based power electronics.
Luksens Technologie GmbH website
Checked 19 Oct 2026

C16M Series | 2 MHz (GaN-optimized) ICS

C16M Series | 2 MHz (GaN-optimized) ICS

Fully integrated differential Hall-effect current sensor with OUT and REF outputs, temperature and stress compensation, adjustable FAULT overcurrent detection, 2 MHz bandwidth, 5 kVrms isolation, and 470 μΩ primary resistance.

Source & evidence

Supplier website
The C16M is a high-performance, fully integrated Hall-effect current sensor employing a differential architecture to effectively suppress external common-mode magnetic interference. It provides a pair of differential outputs (OUT and REF) to maximize the signal-to-noise ratio (SNR) in noisy environments, while integrated temperature and stress compensation ensures high accuracy over a temperature range of -40°C to +125°C, and feature a FAULT overcurrent detection with an externally adjustable overcurrent threshold, saving the cost of additional board-level comparators. The C16M features a 2 MHz (3dB) bandwidth, 5 kVrms isolation, and an ultra-low 470 μΩ primary resistance
Luksens Technologie GmbH website
Checked 19 Oct 2026

Y06-1000WH Close-Loop current sensor

Y06-1000WH Close-Loop current sensor

The Y06 series is a current transducer that operates on magnetic compensation and measures DC, AC or pulse currents and their combinations, with galvanic isolation separating the primary and secondary circuits.

Source & evidence

Supplier website
The Y06 series is a current transducer which operates on the principle of magnetic compensation. Itmeasures DC, AC or pulse currents and their combinations, with galvanic isolation techniques used to separate the primary and secondary circuits.
Luksens Technologie GmbH website
Checked 19 Oct 2026

C08M Series | 2 MHz (GaN-optimized) Integrated Current Sensor

C08M Series | 2 MHz (GaN-optimized) Integrated Current Sensor

The C08M is a high-performance, fully integrated Hall-effect current sensor employing a differential architecture to effectively suppress external common-mode magnetic interference.

Source & evidence

Supplier website
The C08M is a high-performance, fully integrated Hall-effect current sensor employing a differential architecture to effectively suppress external common-mode magnetic interference.
Luksens Technologie GmbH website
Checked 19 Oct 2026

Y06-XXXWH Series

Y06-XXXWH Series

Designed for current measurement up to ±2000 A, with magnetic compensation, galvanic isolation, ±0.02% overall accuracy, and response time under 1 µs.

Source & evidence

Supplier website
Meet the Y06-XXXWH Series: Designed for high-precision current measurement up to ±2000 A, the Y06 leverages the advanced magnetic compensation principle with galvanic isolation. This robust design delivers an outstanding ±0.02% overall accuracy and an ultra-fast response time of under 1 µs.
Luksens Technologie GmbH website
Checked 19 Oct 2026

AC5 series

AC5 series

Open-Loop current sensor; PCB mount.

Source & evidence

Supplier website
100A|200A|300A|400A|500A|600A|700A|800A|900A 1% — PCB mount AC5 series Open-Loop current sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

C02 series

C02 series

Open-Loop current sensor; PCB mount.

Source & evidence

Supplier website
200A|300A|400A|500A|600A|700A|800A 1% — PCB mount C02 series Open-Loop current sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

C03-30A

C03-30A

Open-Loop Current Sensor; PCB mount.

Source & evidence

Supplier website
2.5±0.027V/A 5V 30A 1.50% — PCB mount C03-30A Open-Loop Current Sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

C03-50A

C03-50A

Open-Loop current sensor; PCB mount.

Source & evidence

Supplier website
2.5 ± 0.025V/A 5V 50A 1% — PCB mount C03-50A Open-Loop current sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

C05 series

C05 series

Open-Loop current sensor; PCB mount.

Source & evidence

Supplier website
10A|16A|20A|32A|50A|80A|100A|120A 1% — PCB mount C05 series Open-Loop current sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

C02-XXXAP series

Open-Loop current sensor; PCB mount.

Source & evidence

Supplier website
400A|500A|600A|700A|800A|900A|1000A|1100A|1200A 1% — PCB mount C02-XXXAP series Open-Loop current sensor
Luksens Technologie GmbH website
Checked 19 Oct 2026

Product categories

DC/DC converters

Source & evidence

Trade-fair listing
Power supplies > Power supplies, DC output > DC/DC converter, low power <100W
electronica 2026 exhibitor directory
Checked 26 Sept 2026

Current & magnetic sensors

Source & evidence

Trade-fair listing
Sensor and driving technology > Sensors for electrical and magnetical parameters > Voltage, current
electronica 2026 exhibitor directory
Checked 26 Sept 2026

Pressure, force & mechanical sensors

Source & evidence

Trade-fair listing
Sensor and driving technology > Sensors for mechanical parameters > Pressure (gauge, absolute, differential)
electronica 2026 exhibitor directory
Checked 26 Sept 2026

Temperature sensors

Source & evidence

Trade-fair listing
Sensor and driving technology > Sensors for temperature and caloric parameters > Temperature, temperature distribution
electronica 2026 exhibitor directory
Checked 26 Sept 2026

Test & measurement equipment

Source & evidence

Trade-fair listing
Test and measurement > Mechanical parameters > Pressure meters
electronica 2026 exhibitor directory
Checked 26 Sept 2026

Locations & websites

4 locations · 2 websites

1 of 4 locations have no address precise enough to place; switch to List to see them.

Company websites

www.luksens.de/Found via https://www.luksens.com/

Key capabilities

CapabilityDocumented scopeSupporting source
Technical support and delivery
Technical support and delivery to the global sensor market.
Source & evidence

Supplier website
Luksens offers seamless technical support and top-quality delivery to the global sensor market
Luksens Technologie GmbH website
Checked 19 Oct 2026

Industries served

Company updates

Meet the Y06-XXXWH Series

The story introduces the Y06-XXXWH Series for high-precision current measurement up to ±2000 A.

Source & evidence

Supplier website
Meet the Y06-XXXWH Series: Designed for high-precision current measurement up to ±2000 A, the Y06 leverages the advanced magnetic compensation principle with galvanic isolation. This robust design delivers an outstanding ±0.02% overall accuracy and an ultra-fast response time of under 1 µs.
Luksens Technologie GmbH website
Checked 19 Oct 2026

electronica 2026 in Munich

Luksens says its team will present Hall Effect, Fluxgate, and Pressure Sensors at Hall B4, Booth 248.

Source & evidence

Supplier website
Looking for precise sensor solutions? Meet the Luksens team at electronica 2026 in Munich. We'll show you firsthand how our advanced Hall Effect, Fluxgate, and Pressure Sensors deliver the performance your demanding applications require. Join us at Hall B4, Booth 248!
Luksens Technologie GmbH website
Checked 19 Oct 2026

Common Problems & Solutions for Pressure Sensors

An article about pressure-sensor faults and troubleshooting, including unstable signals, overload damage, zero drift, and slow or absent response.

Source & evidence

Supplier website
Common Problems & Solutions for Pressure Sensors Pressure sensors are critical components in industrial automation and equipment control. Malfunctions directly affect system stability and measurement accuracy. This article summarizes common faults and solutions for quick troubleshooting. 1. Unstable Signal / Abnormal Output Usually caused by unstable power supply, loose wiring, or line faults. Check that the power voltage is within the rated range. Tighten terminals and inspect for corrosion or poor contact. Replace cables or test boards to rule out hardware issues. 2. Overload / Over-range Damage Common in sudden pressure spikes (e.g., improper operation in hydraulic systems). Select a properly rated sensor and install pressure relief / pressure-limiting protection. After replacement, inspect the system pressure control mechanism. 3. Zero Drift Caused by temperature, humidity, or electromagnetic interference, leading to measurement errors. Perform regular zero calibration. Use self-calibrating sensors for high-precision applications. Choose models with strong anti-interference performance. 4. Slow Response / No Response Often due to internal component damage or electrical connection issues. Verify the response speed configuration. Check electrical interfaces and internal sensor faults. Replace the sensor if the problem persists.
Luksens Technologie GmbH website
Checked 19 Oct 2026

Evidence & freshness

Every claim keeps its source. Company-reported information and independent verification are labelled separately. Spot something wrong? .

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 10 facts: Company name · AC5 series · C02 series · C03-30A · C03-50A · C05 series · C02-XXXA33 series · C02-XXXAP series

    2 more

    C02-XXXAP33 series · Location: Meerbusch, Germany

  • electronica 2026 exhibitor directoryTrade-fair listingChecked 26 Sept 2026

    Supports 10 facts: Company name · Description · DC/DC converters · Current & magnetic sensors · Pressure, force & mechanical sensors · Temperature sensors · Test & measurement equipment · Industrial automation

    2 more

    Power electronics & energy · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 7 facts: Company name · Description · Y06-XXXWH Series · Location: Meerbusch, Germany · News: Meet the Y06-XXXWH Series · News: electronica 2026 in Munich · News: Common Problems & Solutions for Pressure Sensors

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 7 facts: Company name · Description · Technical support and delivery · Location: Hong Kong, Hong Kong SAR China · Location: Zhuhai, China · Location: Wuxi, China · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 4 facts: Location: Hong Kong, Hong Kong SAR China · Location: Zhuhai, China · Location: Wuxi, China · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 3 facts: Company name · Y06-1000WH Close-Loop current sensor · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 3 facts: Company name · C08M Series | 2 MHz (GaN-optimized) Integrated Current Sensor · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 3 facts: Company name · C10M Series | 2 MHz (GaN-optimized) ICS · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 3 facts: Company name · C16M Series | 2 MHz (GaN-optimized) ICS · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 2 facts: Company name · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 2 facts: Company name · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 2 facts: Company name · Location: Meerbusch, Germany

  • Luksens Technologie GmbH websiteSupplier websiteChecked 19 Oct 2026

    Supports 1 fact: Company name

What to confirm

A starting point for your supplier conversation.

Manufacturing processesNo source confirms this yet
Services and capabilitiesNo source confirms this yet
CertificationsNo source confirms this yet
Order quantity & lead timeConfirm directly with the supplier

Get in touch

Company contactinfo@luksens.de
Contact sources

Luksens Technologie GmbH website · 19 Oct 2026

Elsewhere online

LinkedIn

Facebook

YouTube

Business type

AI interpretation; these are estimates, not verification.

Manufacturer · 96%
Source & evidence

AI-inferred
Based only on `company`, does this company manufacture its own products (it produces them itself or in its own/controlled factories)?

Design & engineering services · 52%
Source & evidence

AI-inferred
Based only on `company`, does this company offer engineering or product-design services for customers' products (hardware, firmware, PCB layout, product development)?

Is this your company?

Manage products, locations and the facts buyers and agents can retrieve.

Claim this profile Free. A work email on the company’s domain confirms it instantly.

Is something on this profile wrong or out of date?

Answers grounded in company sources

AI can make mistakes. Check sources and confirm requirements with the supplier.